Part of the Auction CNC coordinate measuring machine in portal design
CNC coordinate measuring machine (CMM) in portal design Zeiss CMM CONTURA 7/7/6
Trading #18262-1
Details
Product Type
Zeiss
Type
CMM CONTURA 7/7/6
Description
Supplement subject to change
Measuring volume X = 700 mm, Y = 700 mm, Z = 600 mm
The following specifications apply for:
S1: active sensors VAST XT gold, VAST XTR gold
S2: passive sensor VAST XXT with RDS
Temperature range 18 - 22 °C
Maximum temperature gradients 1.0 K/h; 1.5 K/d; 1.0 K/m
Maximum permissible length measurement error (MPE) according to ISO 10360-2:2009
MPE_E0 (3D) = (1.5 + L/350) µm for S1
MPE_E0 (3D) = (1.7 + L/350) µm for S2
Maximum permissible scanning deviation (MPE) according to ISO 10360-4:2000 within the maximum permissible scanning test time (MPT)
MPE_THP = 2.0 µm in MPT_tau = 40 s for S1
MPE_THP = 2.7 µm in MPT_tau = 50 s for S2
Single probe deviation form according to ISO 10360-5:2010
MPE_PFTU = 1.5 µm for S1
MPE_PFTU = 1.7 µm for S2
Form measurement deviation according to ISO 12181:2011 (VDI/VDE 2617 sheet 2.2)
MPE_RONt (MZCI) = 1.5 µm for S1
MPE_RONt (MZCI) = 1.7 µm for S2
Table height TH = 700 mm
prepared for tactile active and tactile passive sensors for Multi Application Sensor System (mass)
VAST navigator and/or VAST XXT measurement technologies (tactile active scanning and/or tactile passive scanning)
Note:
These measurement technologies only achieve optimal performance when using accessories from ZEISS
PC-based Integrated Scanning Control (ISC) through internal control C99m
Glass-ceramic scales in all 3 axes
Integrated passive vibration damping
AirSaver technology to reduce air consumption
Front protection with control panel holder
A Zeiss technician dismantled the gantry and the entire machine was properly secured, packed, transported and stored
. We will be happy to send you a copy of the service report and the as-is inspection on request.
Measuring volume X = 700 mm, Y = 700 mm, Z = 600 mm
The following specifications apply for:
S1: active sensors VAST XT gold, VAST XTR gold
S2: passive sensor VAST XXT with RDS
Temperature range 18 - 22 °C
Maximum temperature gradients 1.0 K/h; 1.5 K/d; 1.0 K/m
Maximum permissible length measurement error (MPE) according to ISO 10360-2:2009
MPE_E0 (3D) = (1.5 + L/350) µm for S1
MPE_E0 (3D) = (1.7 + L/350) µm for S2
Maximum permissible scanning deviation (MPE) according to ISO 10360-4:2000 within the maximum permissible scanning test time (MPT)
MPE_THP = 2.0 µm in MPT_tau = 40 s for S1
MPE_THP = 2.7 µm in MPT_tau = 50 s for S2
Single probe deviation form according to ISO 10360-5:2010
MPE_PFTU = 1.5 µm for S1
MPE_PFTU = 1.7 µm for S2
Form measurement deviation according to ISO 12181:2011 (VDI/VDE 2617 sheet 2.2)
MPE_RONt (MZCI) = 1.5 µm for S1
MPE_RONt (MZCI) = 1.7 µm for S2
Table height TH = 700 mm
prepared for tactile active and tactile passive sensors for Multi Application Sensor System (mass)
VAST navigator and/or VAST XXT measurement technologies (tactile active scanning and/or tactile passive scanning)
Note:
These measurement technologies only achieve optimal performance when using accessories from ZEISS
PC-based Integrated Scanning Control (ISC) through internal control C99m
Glass-ceramic scales in all 3 axes
Integrated passive vibration damping
AirSaver technology to reduce air consumption
Front protection with control panel holder
A Zeiss technician dismantled the gantry and the entire machine was properly secured, packed, transported and stored
. We will be happy to send you a copy of the service report and the as-is inspection on request.
Location
- Industriestr., 24558 Henstedt-Ulzburg
Parts of this page have been machine translated. The German original text applies.